Intercom Gen 2¶
Support for native local IntercomV2 devices.
Entities¶
Native local IntercomV2 devices are discovered automatically. All entities of
one Intercom are grouped on one device below the Miniserver:
| Entity | Purpose |
|---|---|
| Ringing binary sensor | The bell's ringing state, for dashboards and automations |
| Mute doorbell switch | Mutes/unmutes the Loxone bell; the state follows the Miniserver's feedback |
| Dismiss ringing button | Stops the bell without starting a conversation |
| Output buttons | Pulse the output subcontrols Loxone exposes, such as a door release |
| Play reply buttons | Play the voice replies configured in Loxone; each button shows its text as the message attribute |
| Online binary sensor | Whether the Intercom device is ready |
| Device status sensor | unknown, online, rebooting or initializing |
| Firmware sensor | Diagnostic entity, disabled by default; the firmware is also shown in the device information |
Only the states and outputs Loxone exposes to the configured account become
entities. An output pulse does not report whether a door is actually unlocked.
PIN-protected (secured) Intercoms and outputs get no switch or button; use the
loxone.event_secured_websocket_command action with the code instead. While a
control is locked in Loxone, its switch and buttons are unavailable.
For a ringing notification, trigger on the Ringing sensor changing from off to
on. Repeated presses while it is still ringing are not separate events.
Not supported yet: the camera with two-way audio, Intercoms of a trust member
and custom IntercomV2 devices. This part was written without access to an
Intercom Gen 2; the output buttons in particular are untested on hardware.
Based on the work of jpulik in #542.